Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns

Direct coupling of ion exchange chromatography (IEX) to mass spectrometry (MS) is a game-changer for simplifying workflows and minimising artefacts caused by lengthy isolation steps. While volatile buffers and salts make coupling possible, the high salt concentrations typically used in IEX pose a challenge for MS compatibility. To overcome this, nano-electrospray ionisation (nanoESI) sources, which tolerate high salt concentrations, can be combined with systematic setups like flow splitters (reducing flow to sub-μL/min). However, even greater performance gains can be achieved using IEX columns with smaller inner diameters (ID) and bioinert coated hardware. This setup yields sharper peaks, higher resolution, and optimal recovery—even from the first injection.

This Application Note, based on data from Roche Diagnostics, demonstrates that using a 2.1 mm ID bioinert coated YMC Accura BioPro IEX SF column delivers superior resolution compared to a standard 4.6 mm ID PEEK column when coupled to MS.

UV detection of NISTmAb and trastuzumab

Before MS integration, the method’s effectiveness was validated using UV detection. With detectors installed in series, UV analysis was performed first, followed by MS. High resolution using the YMC Accura BioPro IEX SF column was confirmed by analysing the reference standard NISTmAb and commercially available trastuzumab (Herceptin®), shown in Figure 2.

LC-MS analysis of trastuzumab

The total ion chromatograms (TICs) for trastuzumab analysed with both columns are presented in Figure 3. The YMC Accura BioPro IEX SF column (top) consistently provided sharper peaks and significantly higher resolution compared to the larger-ID PEEK column.

Conclusion

The results demonstrate that the YMC Accura BioPro IEX SF column (2.1 mm ID) is ideally suited for native IEX-MS analysis of monoclonal antibodies, offering superior performance, sharper peaks, and high resolution for demanding workflows.


Events

Korea Lab 2025

Apr 22 2025 Kintex, South Korea

Analytica Anacon India & IndiaLabExpo

Apr 23 2025 Mumbai, India

AOCS Annual Meeting & Expo

Apr 27 2025 Portland, OR, USA

SETAC Europe

May 11 2025 Vienna, Austria

MSB 2025

May 18 2025 Tempe. AZ, USA

View all events

Great Job...
The latest issue will be with you shortly
Sign up to Chromatography Today for FREE.
Register and get the eBulletin, a Monthly email packed with the latest Chromatography products, news and services. Join us and get the latest information first.