• Figure 3: TICs of the analysis of trastuzumab using a YMC Accura BioPro IEX SF column (top) and the corresponding PEEK column (bottom) obtained on different HPLC systems.
  • Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns
    Fig. 1: Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns
  • Fig. 2: Chromatograms obtained for NISTmAb (top) and trastuzumab (bottom) using the YMC Accura BioPro IEX SF column detected with UV.
  • Figure 3: TICs of the analysis of trastuzumab using a YMC Accura BioPro IEX SF column (top) and the corresponding PEEK column (bottom) obtained on different HPLC systems.
  • Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns
    Fig. 1: Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns

Columns (LC)

Native IEX-MS analysis of monoclonal antibodies using YMC Accura BioPro IEX SF columns

Direct coupling of ion exchange chromatography (IEX) to mass spectrometry (MS) is a game-changer for simplifying workflows and minimising artefacts caused by lengthy isolation steps. While volatile buffers and salts make coupling possible, the high salt concentrations typically used in IEX pose a challenge for MS compatibility. To overcome this, nano-electrospray ionisation (nanoESI) sources, which tolerate high salt concentrations, can be combined with systematic setups like flow splitters (reducing flow to sub-μL/min). However, even greater performance gains can be achieved using IEX columns with smaller inner diameters (ID) and bioinert coated hardware. This setup yields sharper peaks, higher resolution, and optimal recovery—even from the first injection.

This Application Note, based on data from Roche Diagnostics, demonstrates that using a 2.1 mm ID bioinert coated YMC Accura BioPro IEX SF column delivers superior resolution compared to a standard 4.6 mm ID PEEK column when coupled to MS.

UV detection of NISTmAb and trastuzumab

Before MS integration, the method’s effectiveness was validated using UV detection. With detectors installed in series, UV analysis was performed first, followed by MS. High resolution using the YMC Accura BioPro IEX SF column was confirmed by analysing the reference standard NISTmAb and commercially available trastuzumab (Herceptin®), shown in Figure 2.

LC-MS analysis of trastuzumab

The total ion chromatograms (TICs) for trastuzumab analysed with both columns are presented in Figure 3. The YMC Accura BioPro IEX SF column (top) consistently provided sharper peaks and significantly higher resolution compared to the larger-ID PEEK column.

Conclusion

The results demonstrate that the YMC Accura BioPro IEX SF column (2.1 mm ID) is ideally suited for native IEX-MS analysis of monoclonal antibodies, offering superior performance, sharper peaks, and high resolution for demanding workflows.


Events

CISILE 2025

Mar 31 2025 Beijing, China

Analytica Vietnam

Apr 02 2025 Saigon, Vietnam

Korea Lab 2025

Apr 22 2025 Kintex, South Korea

Analytica Anacon India & IndiaLabExpo

Apr 23 2025 Mumbai, India

AOCS Annual Meeting & Expo

Apr 27 2025 Portland, OR, USA

View all events

Redirecting you now.
Labmate Awards Nominations - Open
The Labmate Awards for Excellence 2025 seek to recognise innovation, quality and achievement wherever it occurs within the laboratory sector. Launching this year the Labmate Awards for Excellence 2025 will have eleven voting categories chosen to reflect the broad range of noteworthy contributions that have been made across our industry in the past 12 months. Nominate your company Now.