• Figure 1: Protecting groups using the example of an adenosine based phosphoramidite.
  • HPLC Analysis of Phosphoramidites using RP or NP Conditions
    Figure 2: For RP separations a YMC-Triart C18 column was used resulting in sharp peaks.
  • Figure 1: Protecting groups using the example of an adenosine based phosphoramidite.
  • HPLC Analysis of Phosphoramidites using RP or NP Conditions
    Figure 2: For RP separations a YMC-Triart C18 column was used resulting in sharp peaks.

Chromatography

HPLC Analysis of Phosphoramidites using RP or NP Conditions

Maximum flexibility with YMC-Triart

Synthetic oligonucleotides are extremely promising candidates for biopharmaceuticals in a wide range of diseases. This is why nucleic acid therapeutics such as silencing RNA (siRNA), messenger RNA (mRNA) and antisense oligonucleotides (ASOs) are gaining considerable attention in current research.

Phosphoramidites are the essential part of the chemical synthesis of oligonucleotides, short fragments of nucleotides and analogues. To prevent any side reactions on residual reactive sites such as hydroxyl and amino groups during oligonucleotide synthesis, these groups must be protected. Therefore, the highly reactive native nucleotides are modified with four different protecting groups. Figure 1 shows the protecting groups using the example of an adenosine based phosphoramidite.

During the chemical oligonucleotide synthesis, errors can occur which is why the purity of the phosphoramidites needs to be closely monitored. In a new application note two different separation modes - reversed phase (RP) and normal phase (NP) - are used for the analysis of four different phosphoramidites. Due to the complexity of these molecules different interactions can be used in order to achieve reasonable retention and resolution. As phosphoramidites have a chiral centre at the phosphorus atom two isomers are present resulting in double peaks occurring in the chromatograms.

All separations were performed using the highly robust YMC-Triart columns which are an ideal choice for modern biochromatography applications. For RP separations a YMC-Triart C18 column was used resulting in sharp peaks. A YMC-Triart SIL a mobile phase containing triethylamine as additive (examples in Figure 2). Excellent resolution was obtained for all compounds.


Digital Edition

Lab Asia 32.2 April

April 2025

Chromatography Articles - Effects of small deviations in flow rate on GPC/SEC results Mass Spectrometry & Spectroscopy Articles - Waiting for the present to catch up to the future: A bette...

View all digital editions

Events

FORUMESURE

Apr 22 2025 Hammamet, Tunisia

Korea Lab 2025

Apr 22 2025 Kintex, South Korea

Analytica Anacon India & IndiaLabExpo

Apr 23 2025 Mumbai, India

Analitika Expo 2024

Apr 23 2025 Moscow, Russia

Expomed Eurasia

Apr 24 2025 Istanbul, Turkey

View all events

Great Job...
The latest issue will be with you shortly
Sign up to Labmate for FREE.
Register and get the eBulletin, a Monthly email packed with the latest Laboratory products, news and services. Join us and get the latest Laboratory information first.